Make sure that the entire surface is clean and dry.
Replace lower hal t 1 11 siding with cement.
Why would a contractor choose t1 11 siding over cedar siding because your contractor can make a bigger profit by substituting budget materials.
Carefully examine your t1 11 siding for signs of mold wood rot or beyond minor water damage.
Pressured treated wood cedar corrugated metal or plastic a length of concrete siding and probably more.
Add new wall sheathing if the current one is damaged.
T1 11 siding is usually the structural sheathing not merely siding.
It comes in thicknesses of 3 8 of an inch 5 8 of an inch and 3 4 of an inch.
T1 11 was a bad idea in damp climates for a number of reasons.
If the area of the siding you need to repair is larger than two to four inches the best and most permanent solution is to replace that particular panel of siding.
Bv018585 03 27pm 02 03 19.
Before the fiber cement shake panels image 1 go up you ll need to put up the fascia board.
Fiber cement resembling t1 11 cedar siding if you re after the look of t1 11 cedar but wish to get something with less maintenance the allura 8 grove option is a great one.
But breath ability is very important.
Inspect the t1 11 siding carefully.
Water damage is the primary reason it fails.
You can find t1 11 siding in sheets that are 48 inches x 96 inches or 48 inches x 120 inches.
T1 11 siding is a functional siding with great aesthetics so what is the issue with this siding.
Replace any sections that show rot or decay with either new t1 11 or plywood of the same thickness.
You can use plenty of materials for that.
Fiber cement siding is a composite of portland cement silica and wood fibers so it should last much longer than real wood.
Hardie panels are not structural you can t just replace one with the other.
If your going to re side your home with cement board siding don t bother spending the money for t 111 just use exterior grade plywood of the same thickness.
Make sure there is room for the drip to settle and don t let the siding sit in the flashing.
What causes t1 11 siding to fail.
Fiber cement is generally a great option when you re trying to mimic wood but without the maintenance of traditional wood.
So don t caulk between the flashing and the t1 11 siding.
A high quality alternative if real cedar is too expensive is to go with james hardie hardieplank siding.
It s a fiber cement product that is nearly indestructible and is fireproof.
Nor can you overlay compromised t1 11 with a non structural panel and assume that it still meets the structural requirements.